N Male to N Female Bulkhead Low Loss Test
Cable Using PE-P142LL Coax, RoHS
TECHNICAL D PE344
TECHNICAL DATA SHEETATA SHEET
Frequency 4
Frequency, GHz 3
Insertion Loss 0.127 dB/ft [0.42 dB/m ]
Power Handling, Watts 400
Frequency 5
Frequency, GHz 5
Insertion Loss 0.166 dB/ft [0.54 dB/m ]
Power Handling, Watts 300
Frequency 6
Frequency, GHz 10
Insertion Loss 0.24 dB/ft [0.79 dB/m ]
Power Handling, Watts 220
Frequency 7
Frequency, GHz 18
Insertion Loss 0.33 dB/ft [1.08 dB/m ]
Power Handling, Watts 160
Electrical Specification Notes: Power handling values are calculated based on Cable
properties. Power handling will vary based on the actual
VSWR of the cable assembly.
Mechanical Specifications
Cable
Cable Type PE-P142LL
No of Shields 3
Dielectric Type PTFE
Jacket Material FEP
Cable Color Green
Jacket Diameter, in [mm] 0.195 [4.95]
Connector 1
Type N Male
Configuration Straight
Inner Conductor Material and Plating Beryllium Copper, Gold
Inner Conductor Plating Specification ASTM-B488, 50µ Inch.
Outer Conductor Material and Plating Passivated Stainless Steel
Outer Conductor Plating Specification SAE-AMS-2700
Coupling Nut Material and Plating Passivated Stainless Steel
Coupling Nut Plating Specification SAE-AMS-2700
Hex Size, Inch 3/4
Torque, in-lbs [Nm] 14 [1.58]
Dielectric Type PTFE
Click the following link (or enter part number in “SEARCH” on website) to obtain additional part information including price,
inventory and certifications: N Male to N Female Bulkhead Low Loss Test Cable Using PE-P142LL Coax, RoHS PE344