Page 2399 - 1.0/2.3 to SHV RF Connector Datasheets
P. 2399

N Male Connector Clamp/Solder (Captive Contact)
     Attachment for RG213, RG214, RG8, RG9, RG11,
     RG225, RG393, RG144, RG216, RG215

     RF Connectors
     Technical Data Sheet                                                                                    PE4132


                       Assembly Instruction
                                                                                 1
                                                                             2
                                                                         3
                                                                    4
                                                                5
                                                         6 6
                                                  8



                                                               7


                                   1.     SLIDE CLAMP NUT  1 , THIN-WASHER  2   & GASKET  3  OVER CABLE. STRIP CABLE AS SHOWN. DO
                                   NOT NICK BRAID WHILE CUTTING JACKET. TAPER END OF BRAID TO PERMIT ASSEMBLY OF CLAMP.
                                                                           .40
                                                                          10.2




                                   2.     SLIDE BRAID CLAMP  4  OVER BRAID & SEAT AGAINST CABLE. FORM BRAID OVER CLAMP NUT.
                                   TRIM BRAID BACK TO SHOULDER. CUT DIELECTRIC & CENTER CONDUCTOR TO DIMENSION SHOWN.
                                   DO NOT NICK CENTER CONDUCTOR.
                                                              .080
                                                             2.03



                                                                           .200
                                                                          5.08
                                   3.     SLIDE THICK-WASHER  5  AND HALF- INSULATOR  6  AGAINST THE BRAID CLAMP AND HOLD BRAID
                                   IN PLACE. SOLDER CONTACT  7  TO CENTER CONDUCTOR. REMOVE EXCESS SOLDER. DO NOT OVER
                                   HEAT DIELECTRIC.SLIDE A REST HALF- INSULATOR  6  TO LOCKED CONTACT. INSERT CABLE
                                   ASSEMBLY INTO BODY  8  & TIGHTEN.
                                                                       INSULATOR





                                                                   SOLDER











                      Click the following link (or enter part number in “SEARCH” on website) to obtain additional part information including price,
                      inventory and certifications: N Male Connector Clamp/Solder (Captive Contact) Attachment for RG213, RG214, RG8,   -
                      RG9, RG11, RG225, RG393, RG144, RG216, RG215 PE4132                                Pasternack does not make
                any representation or warranty regarding the suitability of the part described herein for any particular purpose, and Pasternack does not assume any liability arising out of the use of any part or documentation.





                                                        PE4132  REV 1.4                                                3
   2394   2395   2396   2397   2398   2399   2400   2401   2402   2403   2404