Page 530 - 1.0/2.3 to SHV RF Connector Datasheets
P. 530
4.3-10 Male Connector Crimp/Non-Solder
Contact Attachment for LMR-240
RF Connectors
Technical Data Sheet EZ-240-4310M-X
Assembly Instruction
.600
15.24
.200
5.08
DEBURR
ASSEMBLY PROCEDURES
1. STRIP CABLE TO THE DIMENSIONS SHOWN, CHAMFER
CENTER CONDUCTOR AND DEBURR CABLE.
2. SLIDE FERRULE OVER CABLE. INSTALL CABLE INTO BODY
OF CONNECTOR UNTIL IT SEATS IN PLACE.
3. SLIDE FERRULE FORWARD AND AGAINST SHOULDER OF
CONNECTOR AND CRIMP.
CRIMP SIZE REQUIRED
• FERRULE: .255" [6.48] HEX CRIMP TOOL.
Click the following link (or enter part number in “SEARCH” on website) to obtain additional part information including price,
inventory and certifications: 4.3-10 Male Connector Crimp/Non-Solder Contact Attachment for LMR-240 EZ-240-4310M-X
-
Pasternack does not make
any representation or warranty regarding the suitability of the part described herein for any particular purpose, and Pasternack does not assume any liability arising out of the use of any part or documentation.
EZ-240-4310M-X REV 1.0 3