Page 3076 - 1.0/2.3 to SHV RF Connector Datasheets
P. 3076

SHV Plug Connector Clamp/Solder Attachment for RG174,
     RG316, RG188, LMR-100, PE-B100, PE-C100, .100 inch


     RF Connectors
     Technical Data Sheet                                                                                    PE4498


                       Assembly Instruction

                                                                         2


                                                              5
                                                         6                        1

                                                                         3
                                                                     4



                                                      7

                                                 ASSEMBLY PROCEDURES
                                       1.   SLIDE CLAMP NUT  1 , THINNER WASHER  2   & GASKET  3  OVER CABLE. STRIP
                                       CABLE AS SHOWN. DO NOT NICK BRAID WHILE CUTTING JACKET. TAPER END OF
                                       BRAID TO PERMIT ASSEMBLY OF CLAMP.
                                                                    .620
                                                                  15.7


                                                       1  2 3
                                       2.   SLIDE BRAID CLAMP  4  OVER BRAID & SEATAGAINST CABLE. FORM BRAID OVER
                                       CLAMP NUT. TRIM BRAID BACK TO SHOULDER. CUT DIELECTRIC & CENTER
                                       CONDUCTOR TO DIMENSION SHOWN. DO NOT NICK CENTER CONDUCTOR.
                                                                    .460
                                                                  11.68

                                                                     .150
                                                                   3.81
                                                       1  2  3  4
                                       3. SLIDE INSULATOR  5  AGAINST THE BRAID CLAMP. SOLDER CONTACT  6  TO
                                       CENTER CONDUCTOR. REMOVE EXCESS SOLDER. DO NOT OVER HEAT DIELECTRIC.
                                       INSERT CABLE ASSEMBLY INTO BODY  7  & TIGHTEN WITH RECOMMENDED TORQUE:
                                       16 in-lbs.
                                                                  5  INSULATOR



                                                            SOLDER


                                             1  2 3  4  5  6        7






                      Click the following link (or enter part number in “SEARCH” on website) to obtain additional part information including price,
                      inventory and certifications: SHV Plug Connector Clamp/Solder Attachment for RG174, RG316, RG188, LMR-100, PE-
                      B100, PE-C100, .100 inch PE4498






                                                        PE4498  REV 1.3                                                3